top of page
Boiler room.jpg

System water contamination or scale problems?
We have experienced staff to solve the problem and get the job done right

Piping system_edited.jpg

We are a unique full Service Company offering Equipment Descaling Service, Water Conditioning, & System Fluid Monitoring Services, and much more.

HydroClean Products provides specialty water and fireside vessel inspection, equipment cleaning and water conditioning services primarily in the industrial and commercial markets. We specialize in preventive maintenance contracts on the water side of your heating and cooling loops, and equipment. We are a specialty service that maintains water quality in heating and cooling loops by monitoring the loops 24/7 with specialized monitoring technology. We make resolving with equipment scaling and system water quality issues, easy. 

​

The boilers of today are much more fuel efficient, but they are less forgiving in terms of scale build-up. The low water mass, combined with thinner walled heat exchangers, and higher heat per sq. ft. of heating surface creates a perfect storm, overtime for a plate-out effect on the water side of the vessel. This is especially apparent on systems that are not chemically treated. In fact, the #1 reason boilers fail is scale. 

​

HydroClean Service has been cleaning commercial and Indutrial boilers for nearly 20 years. We have experience in application, engineering, and system contamination remediation. Cleaning large equipment and specifically boilers is somewhat complicated, and at times can be dangerous. We make the process easy.

​

We have discovered the rate of heat exchanger failures in hydronic systems have risen greatly over the last decade primarily due to scale build-up and poorly maintained system loops. If the water chemistry is not perfect in your heating and cooling loops you are pretty much guaranteed to eventually develop scale on the water side of the boiler, and its the owners responsibility to maintain the water flowing through the boilers and other equipment. 

​

We represent several technologies to help prevent the scale from reacumulating, which includes 24/7 remote monitoring of the heating & cooling building loops to ensure no corrosion or scaling is occurring in the first place. 

​

  • Application support and expert field experience with descaling

  • We offer Water conditioning preventive maintenance contracts

  • The products we use are Non-hazardous and  Non-corrosive

  • Biodegradable and safe to flush down sewers after neutralization

  • Specially formulated corrosion inhibitors to protect metal. 

  • Clean your equipment in place without labor intensive dismantling

  • Equipment can be cleaned in a short amount of time. A typical cleaning will take 4-6 hours depending on thickness of deposition.

  • Our Technicians have been through background checks to comply with Code section 1-111 & PDE-6004 requirements.

  • 24/7 remote water monitoring service with notification, and our technicians will respond within 24 hours to get your system back within parameters to prevent a corrosion or contaminants attack.

  • Thermal Imaging Inspections are a big part of our inspection service and allows us to identify, quantity and ultimately resolve the issues. 

​

 

​

​

 

​

The Cleaning Products used are Biodegradable and Safe for Drain Disposal Once Neutralized

​

The descalers used is a low-pH blend of organic salts. It is a safe and functional replacement for inhibited hydrochloric acid and other corrosive and dangerous acids for scale removal applications. 

​

100% biodegradable, acid Free, and naturally inhibited. No components of of the formula have been identified as carcinogenic by OSHA, NPT, IARC

Descaling & Power Flushing Provides Fast Results, Cost Effective & Provides an Instant Fuel Savings

​

The average turnkey cost of the descaling and flushing service will typically be payed back within 1-2 heating seasons. After the equipment and system has been cleaned, we have a range of products and services to properly maintain the system water.

 

Larger industrial applications the payback is usually less than a year.

 

​

 

​

Restore Peak Efficiencies  & Retain Factory Heat Exchanger Warranties

​

All boiler & water heater manufactures strongly recommend annual water side inspections of the pressure vessel and requires heat exchangers to be clean to ensure long life, perform and maintain factory warranties. 

​

Overheating will cause steel and copper-finned water tube boilers to soften, bulge, and eventually split open due to the weakened metal.

 

Cast iron sectional boilers are most effected by scale (especially magnetite) and will weaken overtime by high internal heat and cyclic fatigue causing uneven expansion and contraction in internal areas of the boiler. 

​

​

Fulcrum2_edited.jpg

Coverage areas we serve for descaling and Water Conditioning Preventive Maintenance Services

WV, PA, MD, OH,

Gas Savings_edited.png

Typical Energy Saved after cleaning Equipment & conditioning water

28%

Easy to Maintain_edited.jpg

Equipment life extended & Factory warranties maintained

Money Payback_edited_edited.png

Average years payback after descaling

1.7

Boiler Water Tube_Scale_edited.jpg

Fact: The #1 Reason Boilers Fail is Caused by Scale. Poor Water Quality & Lack of Proper Maintenance

Studies have shown that only a 1/16" of scale is equivalent to 3" of steel, as a comparison example of reduced heat transfer. Scale deposits act like a thermal barrier on the water side causing expensive heat to be bypassed and exhausted through the flue, in lieu of being absorbed into the hydronic system. 

​

Scale weakens the metal and eventually damages heat exchangers. As system water is flowing through a boiler, the water is heated, and this high internal heat causes minerals to fall out of solution, and plate-out on the hot areas of the heat exchanger. Typically, the scale develops where heat is the highest, and flow is lowest. Also, as the boiler starts and stops, the scale slowly accumulates in thin layers. While this scale is forming in layers, dense magnetite particles are floating around the system and eventually getting encapsulated within the calcium and magnesium layers, further reducing the overall heat transfer. The scale continues to accumulate reducing fuel efficiency, and eventually causes a vessel failure due to overheating.

Dollar Notes

Scale Causes Mechancial Failures & Drastically Reduces Fuel-to-Steam or Water Efficiency

Scale thickness_More Fuel is required_Descale

Click to Enlarge

Scale in Hand.jpg

Fuel prices are approaching all time highs! 

​

Interested in having your equipment evaluated to see how much you can save?

Just a Phone Call Away!

Our experienced network of sales representatives and service professionals will evaluate and provide a solution. We have trained service contractors to perform the descaling services. We have aligned ourselves with well-established service companies with dedicated trained staff, excellent safety records, proper descaling equipment to get the job done cost-effectively, efficiently, and most importantly, done safely. 

​​

Fuel prices are are expected to go much higher. You can't afford not, to keep your boiler clean. Check out the current gas rates in this chart

Click to Enlarge

The Simple Facts About Scale

A clean boiler saves on costly repairs, heat exchanger replacement or possible a complete retube. 

A clean boiler saves more in fuel costs than you could ever spend on water treatment.

Limescale Effect on Heat Transfer

Is HydroCleanse Safe on Metals, Seals & Gaskets? Yes

316 Stainless Steel,

Carbon Steel, Copper, Nickel, Brass, Bronze, Iron, Titanium, Glass

Rubber, Viton, EPDM, PVC, EPDM, Graphite, Teflon, Viton, PTFE

HydroCleanse is non-corrosive and does not erode, attack, oxidize, or have any other harmful affects on virtually any metal or material commonly found in hydronic heating systems.

bottom of page